350' Run 2 Pump Glycol Beer Chiller System 3/4 HP 12 Gallon Tank

$2,930.23
SKU
3K389

The 350' Run 2 Pump Glycol Beer Chiller System with a 12-gallon tank and a 3/4 HP motor is designed for long-draw beer dispensing, supporting up to 350 feet of trunk line for consistent temperature control and quality.

Not the glycol chiller size you were looking for? Find other Rapids glycol chillers here. You can also learn more about choosing the best glycol chiller for your establishment on our blog!

350' Run 2 Pump Glycol Beer Chiller System | 3/4 HP, 12-Gallon Tank

Product Features:

  • 12-gallon glycol tank for extended cooling capacity
  • 3/4 HP compressor for powerful performance
  • 2 pumps for dual trunk line support
  • Digital thermostat for precise temperature management
  • Operates on 208/230 volts with 6.5 amps
  • 1-inch foam insulation for better temperature retention
  • R-134a refrigerant, 16 oz. charge
  • BTU rating: 5800
  • Dimensions: 29" H x 26.5" W x 17" D
  • Weight: 134 lbs.
  • Pump flow rate: 80 GPH
  • Warranty: 1 year parts and labor, 5 years for the compressor

Ensure your beer maintains optimal serving temperature with the 350' Run 2 Pump Long Draw Glycol Beer Chiller System. Engineered for high-capacity performance, this system features a 3/4 HP compressor and a 12-gallon glycol storage tank, allowing it to support up to 350 feet of total cooling line from cooler to faucet. The dual-pump configuration makes it ideal for accommodating two separate trunk lines, providing reliable cooling even for extended setups.

Equipped with a digital thermostat, this glycol chiller ensures precise temperature control to maintain beer quality from keg to tap. Designed for durability, it uses R-134a refrigerant and includes 1-inch foam insulation for enhanced temperature retention. The system operates efficiently with an air-cooled mechanism and has been built for use in various settings, from breweries to bars.

The 350' Run 2 Pump Long Draw Draft Beer Glycol Chiller System with a 12-gallon tank and a robust 3/4 HP compressor is designed for venues that require a reliable and powerful long-draw beer dispensing solution. With the capacity to cool up to 350 feet of trunk line, this chiller ensures that beverages remain at an optimal temperature from storage to faucet, preserving their quality and taste for an exceptional customer experience.

Equipped with a powerful 3/4 HP compressor, this glycol beer chiller can efficiently handle extensive cooling demands, making it ideal for setups with longer distances between the cooler and draft tower. The 12-gallon tank holds a glycol solution mix (70% water, 30% glycol) to maintain consistent cooling, supported by dual pumps that allow for two separate trunk lines. This feature is particularly advantageous for establishments with multiple draft lines or high-volume service needs.

The CWA-34 Glycol Beer Chiller boasts precision temperature control with its digital thermostat, ensuring beverages are consistently kept at the right temperature. Maintaining beer quality during service is crucial, as temperature fluctuations can alter flavor and customer satisfaction. The system’s robust construction includes 1-inch foam insulation to prevent heat exchange, maintaining the chilling power even over long distances.

Designed for efficiency and durability, the chiller includes two pumps that deliver a powerful 80 gallons per hour (GPH) for efficient line cooling. With an approximate pressure of 18 PSI (low) and 150 PSI (high), the system effectively supports the demands of busy bars, breweries, and restaurants. The compact yet sturdy design (dimensions: 29" H x 26.5" W x 17" D) and manageable weight of 134 lbs. make it suitable for tight spaces without sacrificing performance.

Additional features include the use of R-134a refrigerant, known for its effective cooling properties, with a 16 oz. charge to optimize performance. The system is air-cooled, adding convenience by reducing water usage and maintenance complexity. Furthermore, its reliable build ensures long-term operation backed by a one-year parts and labor warranty and a five-year compressor warranty, offering peace of mind and confidence in its investment.

For those with complex or larger draft line systems, the ability to connect multiple beer lines within two trunk lines helps manage service flow and reduce line crowding. Keep in mind that setups with 10 or more beer lines typically double the length of outgoing and return glycol lines, which should be factored into your planning.

Ensure your establishment serves perfectly chilled beer consistently, maintaining the highest standard of taste and quality, with the BVL CWA-34 Glycol Beer Chiller System—an essential addition for high-demand beer service environments.

More Information
Manufacturer Rapids
MPN CWA-34 W/2 PUMP
SKU 3K389
WARNING California Prop 65
This product can expose you to chemicals including Toluene, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov
Write Your Own Review
You're reviewing:350' Run 2 Pump Glycol Beer Chiller System 3/4 HP 12 Gallon Tank
Your Rating

Related Products

You may also be interested in...