3B599
1 HP glycol chiller with 18-gallon tank, 2-pump configuration, 7,500 BTU/hr capacity, and up to 450' run distance. R290 refrigerant. Uses 40% glycol / 60% water mix. Requires at least 12" clearance around entire unit. Operates at 60-90F ambient.

UBC CP7500-2 18 Gallon Glycol Chiller 1 Hp, 450' Run, Dual Pump

Product Features:

  • Cooling capacity: 7,500 BTU/hr
  • Glycol tank: 18 gallons
  • Compressor: 1 HP
  • Max run distance: 450'
  • Pumps: 2 pre-installed (vane type, 1/3 HP, 80 GPH each)
  • Running amps: 10.0 A (1 pump) / 12.8 A (2 pumps)
  • Voltage: 208/230V/60Hz
  • Plug: NEMA 6-20P
  • Inlet/outlet barb: 3/8"
  • Refrigerant: R290
  • Operating ambient: 60–90°F
  • Glycol mix: 40% glycol / 60% water
  • Required clearance: 12" around entire unit

The CP7500-2 is a commercial glycol chiller engineered to maintain draft beer line temperatures over distances up to 450 feet, supporting 2-pump operation with a 18-gallon glycol tank and 7,500 BTU/hr cooling capacity. Operating on R290 refrigerant with a 40% glycol / 60% water mixture, it keeps beer lines at serving temperature from keg coupler to faucet - eliminating foam caused by warm lines between pours.

The 1 HP compressor runs on 208/230V/60Hz and requires a minimum 12" clearance around the entire unit for proper airflow. The 3/8" inlet/outlet barbs connect to standard glycol trunk line fittings, and the unit operates reliably in ambient temperatures of 60–90°F. A proven glycol chiller solution for breweries, bars, and multi-tap draft installations requiring reliable temperature control over long runs.

Spec SheetSpec Sheet

The CP7500-2 glycol chiller is the refrigeration backbone of any long-run draft beer system - the equipment that keeps beverage lines at serving temperature from the keg room to the faucet, regardless of how far apart those two points are. Without a functioning glycol chiller, beer in long lines warms between pours and delivers the first glass of every service as foam - a problem that the CP7500-2 eliminates by continuously circulating chilled glycol through insulated trunk lines.

With a cooling capacity of 7,500 BTU/hr and a maximum run distance of 450 feet, the CP7500-2 is sized for long-run draft installations - covering multi-zone bars and restaurants with remote keg storage. The 18-gallon glycol tank provides thermal mass to buffer against peak cooling demand during high-volume service periods.

Two vane pumps are pre-installed, each with a 1/3 HP motor delivering 80 GPH - the correct flow rate for maintaining glycol velocity through the trunk line without over-pressurizing the system. The 1 HP compressor operates on 208/230V/60Hz at 10.0 A (1 pump) / 12.8 A (2 pumps). The 3/8" inlet/outlet barbs are the standard connection size for commercial glycol trunk line systems.

R290 refrigerant is used throughout - a natural hydrocarbon refrigerant with minimal global warming potential and excellent thermodynamic efficiency. The unit operates reliably in ambient temperatures of 60–90°F°F, and requires at least 12" of clearance around the entire unit for proper airflow and service access. The glycol mixture specification of 40% glycol to 60% water is important to follow precisely - deviating from this ratio affects both freeze protection and heat transfer efficiency.

A commercial-grade glycol chiller for operators who understand that consistent beverage temperature is not optional - it's what separates a well-run draft system from one that wastes product and frustrates customers.

More Information
Horsepower 1
Number of Pumps Dual Pump
Line Capacity (Feet) Over 300
Orientation Vertical
Refrigerant Type R290
Capacity 18
BTU 7500
Voltage 208-230v/60hz/1ph
Amps (A) 20
Plug Type NEMA 6-20P
Product Weight (lbs) 140
Product Width (in) 28.8
Product Length (in) 23.5
Product Height (in) 35.6
Manufacturer UBC
MPN CP7500-2
SKU 3B599