UBC 19 Gallon Glycol Chiller 1+1 Hp, 750' Run, Dual Pump, Water Cooled
UBC CP13000-WC-2 19 Gallon Glycol Chiller 1+1 Hp, 750' Run, Dual Pump, Water Cooled
Product Features:
- Cooling capacity: 13,000 BTU/hr
- Glycol tank: 18 gallons
- Compressor: 1+1 HP
- Max run distance: 750'
- Pumps: 2 pre-installed (vane type, 1/3 HP, 80 GPH each)
- Running amps: 12.2 A (1 pump) / 15.0 A (2 pumps)
- Voltage: 208/230V/60Hz; Plug: 6-20P or Hard Wire
- Inlet/outlet barb: 3/8"
- Refrigerant: R290
- Operating ambient: 60–90°F
- Glycol mix: 40% glycol / 60% water
- Required clearance: 12" around entire unit
- Water inlet/outlet: 3/8-18 NPT; Water pressure: 40–150 psi
- Min flow rate: 2.0 gpm min
- Water-cooled condenser - no ambient heat rejection required
The CP13000-WC-2 is a commercial glycol chiller engineered to maintain draft beer line temperatures over distances up to 750 feet, supporting 2-pump operation with a 18-gallon glycol tank and 13,000 BTU/hr cooling capacity. Operating on R290 refrigerant with a 40% glycol / 60% water mixture, it keeps beer lines at serving temperature from keg coupler to faucet - eliminating foam caused by warm lines between pours. The water-cooled condenser design eliminates the need to manage ambient heat rejection in the installation space - critical for enclosed or high-ambient-temperature environments where air-cooled units would struggle to maintain performance.
The 1+1 HP compressor runs on 208/230V/60Hz and requires a minimum 12" clearance around the entire unit for proper airflow. The 3/8" inlet/outlet barbs connect to standard glycol trunk line fittings, and the unit operates reliably in ambient temperatures of 60–90°F. A proven glycol chiller solution for breweries, bars, and multi-tap draft installations requiring reliable temperature control over long runs.


The CP13000-WC-2 glycol chiller is the refrigeration backbone of any long-run draft beer system - the equipment that keeps beverage lines at serving temperature from the keg room to the faucet, regardless of how far apart those two points are. Without a functioning glycol chiller, beer in long lines warms between pours and delivers the first glass of every service as foam - a problem that the CP13000-WC-2 eliminates by continuously circulating chilled glycol through insulated trunk lines.
With a cooling capacity of 13,000 BTU/hr and a maximum run distance of 750 feet, the CP13000-WC-2 is sized for high-capacity long-run draft installations - covering large breweries, stadiums, and multi-zone venue draft systems. The 18-gallon glycol tank provides thermal mass to buffer against peak cooling demand during high-volume service periods.
The water-cooled condenser is the defining feature that separates the CP13000-WC-2 from air-cooled glycol chillers. In environments where the chiller is located in a mechanical room, basement, or any enclosed space where ambient temperatures are elevated or airflow is restricted, a water-cooled unit maintains full rated performance regardless of room conditions. The 3/8-18 NPT water inlet and outlet connect to a standard building water supply, with a minimum flow rate of 2.0 GPM and inlet pressure between 40–150 psi.
Two vane pumps are pre-installed, each with a 1/3 HP motor delivering 80 GPH - the correct flow rate for maintaining glycol velocity through the trunk line without over-pressurizing the system. The 1+1 HP compressor operates on 208/230V/60Hz at 12.2 A (1 pump) / 15.0 A (2 pumps). The 3/8" inlet/outlet barbs are the standard connection size for commercial glycol trunk line systems.
R290 refrigerant is used throughout - a natural hydrocarbon refrigerant with minimal global warming potential and excellent thermodynamic efficiency. The unit operates reliably in ambient temperatures of 60–90°F°F, and requires at least 12" of clearance around the entire unit for proper airflow and service access. The glycol mixture specification of 40% glycol to 60% water is important to follow precisely - deviating from this ratio affects both freeze protection and heat transfer efficiency.
A commercial-grade glycol chiller for operators who understand that consistent beverage temperature is not optional - it's what separates a well-run draft system from one that wastes product and frustrates customers.
| Horsepower | 2 |
|---|---|
| Number of Pumps | Dual Pump |
| Line Capacity (Feet) | Over 300 |
| Orientation | Vertical |
| Refrigerant Type | R290 |
| Capacity | 19 |
| BTU | 13000 |
| Voltage | 230-260v/50hz/1ph |
| Amps (A) | 20 |
| Plug Type | NEMA 6-20P |
| Product Weight (lbs) | 220 |
| Product Width (in) | 28.8 |
| Product Length (in) | 23.5 |
| Product Height (in) | 38 |
| Manufacturer | UBC |
| MPN | CP13000-WC-2 |
| SKU | 3B603 |