UBC 19 Gallon Glycol Chiller 1+1 Hp, 750' Run, Dual Pump, Water Cooled

$6,768.00
SKU
3B603
1+1 HP water-cooled glycol chiller with 18-gallon tank, 2-pump configuration, 13,000 BTU/hr capacity, and up to 750' run distance. R290 refrigerant. Uses 40% glycol / 60% water mix. Requires at least 12" clearance around entire unit. Operates at 60-90F ambient.

UBC CP13000-WC-2 19 Gallon Glycol Chiller 1+1 Hp, 750' Run, Dual Pump, Water Cooled

Product Features:

  • Cooling capacity: 13,000 BTU/hr
  • Glycol tank: 18 gallons
  • Compressor: 1+1 HP
  • Max run distance: 750'
  • Pumps: 2 pre-installed (vane type, 1/3 HP, 80 GPH each)
  • Running amps: 12.2 A (1 pump) / 15.0 A (2 pumps)
  • Voltage: 208/230V/60Hz; Plug: 6-20P or Hard Wire
  • Inlet/outlet barb: 3/8"
  • Refrigerant: R290
  • Operating ambient: 60–90°F
  • Glycol mix: 40% glycol / 60% water
  • Required clearance: 12" around entire unit
  • Water inlet/outlet: 3/8-18 NPT; Water pressure: 40–150 psi
  • Min flow rate: 2.0 gpm min
  • Water-cooled condenser - no ambient heat rejection required

The CP13000-WC-2 is a commercial glycol chiller engineered to maintain draft beer line temperatures over distances up to 750 feet, supporting 2-pump operation with a 18-gallon glycol tank and 13,000 BTU/hr cooling capacity. Operating on R290 refrigerant with a 40% glycol / 60% water mixture, it keeps beer lines at serving temperature from keg coupler to faucet - eliminating foam caused by warm lines between pours. The water-cooled condenser design eliminates the need to manage ambient heat rejection in the installation space - critical for enclosed or high-ambient-temperature environments where air-cooled units would struggle to maintain performance.

The 1+1 HP compressor runs on 208/230V/60Hz and requires a minimum 12" clearance around the entire unit for proper airflow. The 3/8" inlet/outlet barbs connect to standard glycol trunk line fittings, and the unit operates reliably in ambient temperatures of 60–90°F. A proven glycol chiller solution for breweries, bars, and multi-tap draft installations requiring reliable temperature control over long runs.

Spec SheetSpec Sheet

The CP13000-WC-2 glycol chiller is the refrigeration backbone of any long-run draft beer system - the equipment that keeps beverage lines at serving temperature from the keg room to the faucet, regardless of how far apart those two points are. Without a functioning glycol chiller, beer in long lines warms between pours and delivers the first glass of every service as foam - a problem that the CP13000-WC-2 eliminates by continuously circulating chilled glycol through insulated trunk lines.

With a cooling capacity of 13,000 BTU/hr and a maximum run distance of 750 feet, the CP13000-WC-2 is sized for high-capacity long-run draft installations - covering large breweries, stadiums, and multi-zone venue draft systems. The 18-gallon glycol tank provides thermal mass to buffer against peak cooling demand during high-volume service periods.

The water-cooled condenser is the defining feature that separates the CP13000-WC-2 from air-cooled glycol chillers. In environments where the chiller is located in a mechanical room, basement, or any enclosed space where ambient temperatures are elevated or airflow is restricted, a water-cooled unit maintains full rated performance regardless of room conditions. The 3/8-18 NPT water inlet and outlet connect to a standard building water supply, with a minimum flow rate of 2.0 GPM and inlet pressure between 40–150 psi.

Two vane pumps are pre-installed, each with a 1/3 HP motor delivering 80 GPH - the correct flow rate for maintaining glycol velocity through the trunk line without over-pressurizing the system. The 1+1 HP compressor operates on 208/230V/60Hz at 12.2 A (1 pump) / 15.0 A (2 pumps). The 3/8" inlet/outlet barbs are the standard connection size for commercial glycol trunk line systems.

R290 refrigerant is used throughout - a natural hydrocarbon refrigerant with minimal global warming potential and excellent thermodynamic efficiency. The unit operates reliably in ambient temperatures of 60–90°F°F, and requires at least 12" of clearance around the entire unit for proper airflow and service access. The glycol mixture specification of 40% glycol to 60% water is important to follow precisely - deviating from this ratio affects both freeze protection and heat transfer efficiency.

A commercial-grade glycol chiller for operators who understand that consistent beverage temperature is not optional - it's what separates a well-run draft system from one that wastes product and frustrates customers.

More Information
Horsepower 2
Number of Pumps Dual Pump
Line Capacity (Feet) Over 300
Orientation Vertical
Refrigerant Type R290
Capacity 19
BTU 13000
Voltage 230-260v/50hz/1ph
Amps (A) 20
Plug Type NEMA 6-20P
Product Weight (lbs) 220
Product Width (in) 28.8
Product Length (in) 23.5
Product Height (in) 38
Manufacturer UBC
MPN CP13000-WC-2
SKU 3B603
Write Your Own Review
You're reviewing:UBC 19 Gallon Glycol Chiller 1+1 Hp, 750' Run, Dual Pump, Water Cooled
Your Rating

You may also be interested in...